The range of Mitsubishi Heavy Industries outdoor air conditioning units, designed to operate with the eco-friendly R32 refrigerant, offers cooling capacities from 3.00 kW to 10.00 kW. The unit allows for the operation of a Multi-Split system with a maximum of five indoor units, providing a total cooling capacity of 16.00 kW. These units, equipped with high-efficiency DC Twin rotary compressors, ensure excellent energy performance with SEER/SCOP ratings of up to 9.20/4.80, along with low vibration and noise levels. All units feature a quiet mode for reduced noise.

Parameters

Model
ascending
Cooling capacity [kW]
ascending
Heating capacity [kW]
ascending
Maximum refrigerant line length [m]
ascending
Maximum number of indoor units
ascending
Acoustic pressure (cooling mode) [dB(A)]
ascending
Acoustic pressure (heating mode) [dB(A)]
Dostępność
Cena
Porównaj

SCM30ZS-W

Cooling capacity [kW]:
3.00
Heating capacity [kW]:
4.00
Maximum refrigerant line length [m]:
30
Maximum number of indoor units:
2
Acoustic pressure (cooling mode) [dB(A)]:
49.0
Acoustic pressure (heating mode) [dB(A)]:
51.0
Dostępność:
Niedostępny
Cena:
Na zapytanie

SCM40ZS-W

Cooling capacity [kW]:
4.00
Heating capacity [kW]:
4.50
Maximum refrigerant line length [m]:
30
Maximum number of indoor units:
2
Acoustic pressure (cooling mode) [dB(A)]:
49.0
Acoustic pressure (heating mode) [dB(A)]:
51.0
Dostępność:
Niedostępny
Cena:
Na zapytanie

SCM45ZS-W

Cooling capacity [kW]:
4.50
Heating capacity [kW]:
5.30
Maximum refrigerant line length [m]:
30
Maximum number of indoor units:
2
Acoustic pressure (cooling mode) [dB(A)]:
50.0
Acoustic pressure (heating mode) [dB(A)]:
52.0
Dostępność:
Niedostępny
Cena:
Na zapytanie

SCM41ZS-W

Cooling capacity [kW]:
4.00
Heating capacity [kW]:
4.50
Maximum refrigerant line length [m]:
40
Maximum number of indoor units:
3
Acoustic pressure (cooling mode) [dB(A)]:
49.0
Acoustic pressure (heating mode) [dB(A)]:
52.0
Dostępność:
Niedostępny
Cena:
Na zapytanie

SCM50ZS-W

Cooling capacity [kW]:
5.00
Heating capacity [kW]:
6.00
Maximum refrigerant line length [m]:
40
Maximum number of indoor units:
3
Acoustic pressure (cooling mode) [dB(A)]:
49.0
Acoustic pressure (heating mode) [dB(A)]:
52.0
Dostępność:
Niedostępny
Cena:
Na zapytanie

SCM60ZS-W

Cooling capacity [kW]:
6.00
Heating capacity [kW]:
6.80
Maximum refrigerant line length [m]:
40
Maximum number of indoor units:
3
Acoustic pressure (cooling mode) [dB(A)]:
50.0
Acoustic pressure (heating mode) [dB(A)]:
52.0
Dostępność:
Niedostępny
Cena:
Na zapytanie

SCM71ZS-W

Cooling capacity [kW]:
7.10
Heating capacity [kW]:
8.60
Maximum refrigerant line length [m]:
70
Maximum number of indoor units:
4
Acoustic pressure (cooling mode) [dB(A)]:
50.0
Acoustic pressure (heating mode) [dB(A)]:
54.0
Dostępność:
Niedostępny
Cena:
Na zapytanie

SCM80ZS-W

Cooling capacity [kW]:
8.00
Heating capacity [kW]:
9.30
Maximum refrigerant line length [m]:
70
Maximum number of indoor units:
4
Acoustic pressure (cooling mode) [dB(A)]:
54.0
Acoustic pressure (heating mode) [dB(A)]:
54.0
Dostępność:
Niedostępny
Cena:
Na zapytanie

SCM100ZS-W

Cooling capacity [kW]:
10.00
Heating capacity [kW]:
10.50
Maximum refrigerant line length [m]:
75
Maximum number of indoor units:
5
Acoustic pressure (cooling mode) [dB(A)]:
54.0
Acoustic pressure (heating mode) [dB(A)]:
59.0
Dostępność:
Niedostępny
Cena:
Na zapytanie

Due to frequent changes and updates, presented data are provided on illustrative basis only. All materials contained on this website are protected by copyright and their use, copying and publishing in any form is prohibited without the written consent of Elektronika SA. Please read the full Terms of Use.

Sales of equipment

We are a direct importer, representative and authorized distributor of the world's leading refrigeration and air conditioning manufacturers. The main activity of the company is wholesale and distribution of HVACR equipment and accessories, including heat pumps and chillers, through its own network of branches.

Check our offer

Technical support

We actively support our HVACR Installers and Designers. We organize product trainings; provide assistance and technical advice to refrigeration and air conditioning engineers at every stage of the investment realization. Hundreds of successful investments confirm our competence and extensive experience.

Check our offer

Investment processes

Our organizational structures include Investment Implementation Departments, which, based on the skills of engineers and designers, in cooperation with installation companies from the investment area, are able to design and implement the most modern cooling, freezing and air conditioning units.

Check our offer

Cookies information

This website uses cookies to improve the quality of the services provided. It also uses the Third-Party cookies, they provide tools and solutions that improve the ergonomics and functionality of the website, such as video playback, website usage analytics and marketing content customization.

By clicking accept, you agree to use cookies, as outlined in our Cookie Policy

Send feedback
Report an error