Producer:
Danfoss
  • Maximal nominal capacity (LBP) [kW]:
    10.2
  • Maximal nominal capacity (MBP) [kW]:
    19.6
  • Refrigerant:
    R744 (CO₂)
  • Capacity control:
    Inverter (standard)
  • Power supply:
    400V/3Ph/50Hz
Cena na zapytanie
Niedostępny

Opis do wyświetlenia w tooltipie

Zapytaj

Data

Compressor technical data

Capacity control
Inverter (standard)
Oil type
MA 68
Approvals
CE, UKCA

Compressor electrical data

Compressor power supply
400V/3Ph/50Hz
Maximum continuous current
[A]
19.0
Rated load amps
[A]
16.5
Minimal fuse current
[A]
25.0

Condenser data

Fan power supply
230V/1Ph/50Hz
Fan quantity
2
Fan diameter
[mm]
570
Fan current
[A]
3.65
Inner volume
[dm³]
6.1
Air flow
[m³/h]
15,120
Acoustic power
[dB(A)]
62.0
Acoustic pressure (10m)
[dB(A)]
42.0

Condensing unit data

Product codes
114x6003
Receiver quantity
2
Receiver volume
[l]
7.6
Suction line accumulator volume
[l]
7.2
Oil separator volume
[l]
0.87
Net weight
[kg]
340
Gross weight
[kg]
360.00
Housing
Yes
Approved refrigerants
R744 (CO₂)
Mandatory equipment
Module controller assembly

Dimensions

Length
[mm]
1,350
Height
[mm]
1,692
Width
[mm]
764
Suction valve diameter
[inch]
3/4
Liquid line diameter
[inch]
1/2

Limits

Maximum suction pressure
[bar]
80.0
Maximum discharge pressure
[bar]
140.0
Minimal ambient temperature
[°C]
-20
Maximum ambient temperature
[°C]
43

Performance

Cooling capacity [kW]

Evaporation temperature [°C]
Ambient temperature [°C]
 
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
5
5
9.16
10.45
12.16
14.00
15.90
17.66
19.75
21.83
23.35
25.69
28.14
10
8.98
10.25
11.93
13.76
15.74
17.78
19.83
21.71
22.90
24.89
23.37
15
8.95
10.06
11.70
13.49
15.42
17.40
19.10
21.00
23.70
24.41
24.44
20
8.74
9.79
11.37
13.11
14.97
16.91
18.71
20.61
22.81
25
8.53
9.51
11.05
12.72
14.51
16.41
18.32
20.22
21.93
30
7.57
8.68
10.37
12.11
13.87
15.72
17.61
19.48
20.90
35
6.79
8.22
10.02
11.64
13.29
15.02
16.62
18.62
19.50

Conditions: superheating: 10 K.

Power consumption [kW]

Evaporation temperature [°C]
Ambient temperatura [°C]
 
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
5
5
5.21
4.84
4.80
4.68
4.63
4.49
4.36
4.28
6.52
6.17
5.69
10
6.11
6.07
6.13
6.11
6.00
5.90
5.75
5.54
6.77
6.45
6.52
15
6.51
6.24
6.65
6.27
6.15
6.04
5.81
5.94
7.39
6.96
6.58
20
8.09
7.33
7.63
7.45
7.39
7.32
7.11
7.09
7.82
25
9.67
8.42
8.61
8.62
8.63
8.60
8.41
8.24
8.25
30
10.25
9.70
9.80
9.86
9.90
9.90
9.83
9.72
9.58
35
10.33
10.73
11.04
11.07
11.09
11.10
10.97
11.07
10.70

Conditions: superheating: 10 K.

Application range (maximal speed)

Application range is valid for the highest value of revolution per minute.

Dimensions

Symbols

A Power cable inlet [nbsp]
B Sight glass [nbsp]
C Check port for 7-segment display [nbsp]
D Air in [nbsp]

[nbsp]

E Air out [nbsp]
F Liquid port [nbsp]
G Suction port [nbsp]
H Power cable connection terminal block [nbsp]

Downloads

Optyma iCO₂ (OP-UP version) condensing units Declaration of Conformity
Declaration, [121.4 KB]
Danfoss
12-2022
EN
Optyma iCO₂ (OP-UP version) condensing units Declaration of incorporation
Declaration, [132.8 KB]
Danfoss
12-2022
EN
Optyma iCO₂ (OP-UP version) condensing units installation manual
Technical documentation, [6.3 MB]
Danfoss
07-2024
EN
Optyma iCO₂ (OP-UP version) condensing units installation manual
Technical documentation, [6.5 MB]
Danfoss
07-2024
PL
Optyma iCO₂ (OP-UP version) condensing units technical documentation
Technical documentation, [7.0 MB]
Danfoss
03-2024
EN
Optyma iCO₂ condensing units Modbus connection tables
User manual, [349.9 KB]
Danfoss
08-2023
EN
Optyma iCO₂ condensing units module controller technical documentation
Technical documentation, [2.1 MB]
Danfoss
01-2024
EN
Optyma iCO₂ condensing units module controller technical documentation
Technical documentation, [2.1 MB]
Danfoss
02-2023
PL
Optyma iCO₂ (OP-UP version) condensing units Declaration of Conformity
Declaration, EN, Danfoss, 12-2022, [121.4 KB]
Optyma iCO₂ (OP-UP version) condensing units Declaration of incorporation
Declaration, EN, Danfoss, 12-2022, [132.8 KB]
Optyma iCO₂ (OP-UP version) condensing units installation manual
Technical documentation, EN, Danfoss, 07-2024, [6.3 MB]
Optyma iCO₂ (OP-UP version) condensing units installation manual
Technical documentation, PL, Danfoss, 07-2024, [6.5 MB]
Optyma iCO₂ (OP-UP version) condensing units technical documentation
Technical documentation, EN, Danfoss, 03-2024, [7.0 MB]
Optyma iCO₂ condensing units Modbus connection tables
User manual, EN, Danfoss, 08-2023, [349.9 KB]
Optyma iCO₂ condensing units module controller technical documentation
Technical documentation, EN, Danfoss, 01-2024, [2.1 MB]
Optyma iCO₂ condensing units module controller technical documentation
Technical documentation, PL, Danfoss, 02-2023, [2.1 MB]

Due to frequent changes and updates, presented data are provided on illustrative basis only. All materials contained on this website are protected by copyright and their use, copying and publishing in any form is prohibited without the written consent of Elektronika SA. Please read the full Terms of Use.

Sales of equipment

We are a direct importer, representative and authorized distributor of the world's leading refrigeration and air conditioning manufacturers. The main activity of the company is wholesale and distribution of HVACR equipment and accessories, including heat pumps and chillers, through its own network of branches.

Check our offer

Technical support

We actively support our HVACR Installers and Designers. We organize product trainings; provide assistance and technical advice to refrigeration and air conditioning engineers at every stage of the investment realization. Hundreds of successful investments confirm our competence and extensive experience.

Check our offer

Investment processes

Our organizational structures include Investment Implementation Departments, which, based on the skills of engineers and designers, in cooperation with installation companies from the investment area, are able to design and implement the most modern cooling, freezing and air conditioning units.

Check our offer

Cookies information

This website uses cookies to improve the quality of the services provided. It also uses the Third-Party cookies, they provide tools and solutions that improve the ergonomics and functionality of the website, such as video playback, website usage analytics and marketing content customization.

By clicking accept, you agree to use cookies, as outlined in our Cookie Policy

Send feedback
Report an error