Сheck valves Danfoss NRV designed for use in liquid and suction lines as well as hot gas lines of refrigeration and air conditioning systems. They are intended for work with HCFC, HFC and HC flammable refrigerants. They are used to control the unidirectional flow of refrigerant so as to prevent backflow. Built-in damping piston that makes the valves suitable for installation in lines where pulsation can occur, e.g. in the discharge line from the compressor. Special models are available for CO2 units with maximum operating pressure 90 bar.

[read more]

Parameters

Performance

All

All

All

All

Selection parameters
Evaporation
Condensation
Model
ascending
Inlet connection type
ascending
Inlet connection diameter
ascending
Body geometry
ascending
Maximum operating pressure [bar]
ascending
Inlet flow speed [m/s]
ascending
Pressure drop [bar]
Dostępność
Cena
Porównaj

NRV 6

Inlet connection type:
Flare
Inlet connection diameter:
1/4"
Body geometry:
Straightway
Maximum operating pressure [bar]:
46
Inlet flow speed [m/s]:
7.98
Pressure drop [bar]:
0.28
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 6s

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
1/4", 3/8", 6 mm, 10 mm
Body geometry:
Straightway
Maximum operating pressure [bar]:
49
Inlet flow speed [m/s]:
7.98
Pressure drop [bar]:
0.28
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 10

Inlet connection type:
Flare
Inlet connection diameter:
3/8"
Body geometry:
Straightway
Maximum operating pressure [bar]:
46
Inlet flow speed [m/s]:
2.00
Pressure drop [bar]:
0.08
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 10s

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
3/8", 1/2", 10 mm, 12 mm
Body geometry:
Straightway
Maximum operating pressure [bar]:
49
Inlet flow speed [m/s]:
2.00
Pressure drop [bar]:
0.08
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 12

Inlet connection type:
Flare
Inlet connection diameter:
1/2"
Body geometry:
Straightway
Maximum operating pressure [bar]:
46
Inlet flow speed [m/s]:
1.58
Pressure drop [bar]:
0.03
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 12s

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
1/2", 5/8", 12 mm
Body geometry:
Straightway
Maximum operating pressure [bar]:
49
Inlet flow speed [m/s]:
1.58
Pressure drop [bar]:
0.03
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 16

Inlet connection type:
Flare
Inlet connection diameter:
5/8"
Body geometry:
Straightway
Maximum operating pressure [bar]:
46
Inlet flow speed [m/s]:
0.76
Pressure drop [bar]:
0.03
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 16s

Inlet connection type:
Soldered, ODM (inch), Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
1/2", 5/8", 3/4", 18 mm, 19 mm
Body geometry:
Straightway
Maximum operating pressure [bar]:
49
Inlet flow speed [m/s]:
0.76
Pressure drop [bar]:
0.03
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 19

Inlet connection type:
Flare
Inlet connection diameter:
3/4"
Body geometry:
Straightway
Maximum operating pressure [bar]:
46
Inlet flow speed [m/s]:
0.57
Pressure drop [bar]:
0.02
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 19s

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
3/4", 7/8", 18 mm, 19 mm
Body geometry:
Straightway
Maximum operating pressure [bar]:
49
Inlet flow speed [m/s]:
0.57
Pressure drop [bar]:
0.02
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 22s

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
7/8", 1 1/8", 28 mm
Body geometry:
Angleway
Maximum operating pressure [bar]:
46
Inlet flow speed [m/s]:
0.35
Pressure drop [bar]:
0.02
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 22s E

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
7/8", 1 1/8", 28 mm
Body geometry:
Angleway
Maximum operating pressure [bar]:
49
Inlet flow speed [m/s]:
Pressure drop [bar]:
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 28s

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
1 1/8", 1 3/8", 28 mm
Body geometry:
Angleway
Maximum operating pressure [bar]:
46
Inlet flow speed [m/s]:
0.20
Pressure drop [bar]:
0.02
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 28s E

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
1 1/8", 1 3/8", 28 mm
Body geometry:
Angleway
Maximum operating pressure [bar]:
49
Inlet flow speed [m/s]:
Pressure drop [bar]:
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 35s

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
1 3/8", 1 5/8", 42 mm
Body geometry:
Angleway
Maximum operating pressure [bar]:
46
Inlet flow speed [m/s]:
0.12
Pressure drop [bar]:
0.02
Dostępność:
Niedostępny
Cena:
Na zapytanie

NRV 35s E

Inlet connection type:
Soldered, ODF (mm), Soldered, ODF (inch)
Inlet connection diameter:
1 3/8", 1 5/8", 42 mm
Body geometry:
Angleway
Maximum operating pressure [bar]:
49
Inlet flow speed [m/s]:
Pressure drop [bar]:
Dostępność:
Niedostępny
Cena:
Na zapytanie

Сheck valves Danfoss NRV are available in straight and angle versions, it solve the resonance problem with partial thermal load on the cooling system.

Soldered versions of NRV are compliant with ATEX hazard zone 2.

Application:

  • Traditional refrigeration
  • Heat pump systems
  • Air conditioning units
  • Liquid coolers
  • Transport refrigeration

Due to frequent changes and updates, presented data are provided on illustrative basis only. All materials contained on this website are protected by copyright and their use, copying and publishing in any form is prohibited without the written consent of Elektronika SA. Please read the full Terms of Use.

Sales of equipment

We are a direct importer, representative and authorized distributor of the world's leading refrigeration and air conditioning manufacturers. The main activity of the company is wholesale and distribution of HVACR equipment and accessories, including heat pumps and chillers, through its own network of branches.

Check our offer

Technical support

We actively support our HVACR Installers and Designers. We organize product trainings; provide assistance and technical advice to refrigeration and air conditioning engineers at every stage of the investment realization. Hundreds of successful investments confirm our competence and extensive experience.

Check our offer

Investment processes

Our organizational structures include Investment Implementation Departments, which, based on the skills of engineers and designers, in cooperation with installation companies from the investment area, are able to design and implement the most modern cooling, freezing and air conditioning units.

Check our offer

Cookies information

This website uses cookies to improve the quality of the services provided. It also uses the Third-Party cookies, they provide tools and solutions that improve the ergonomics and functionality of the website, such as video playback, website usage analytics and marketing content customization.

By clicking accept, you agree to use cookies, as outlined in our Cookie Policy

Send feedback
Report an error